This solar panel compatibility checker compares your panels with a power station’s solar input limits: maximum voltage, current and power, including the extra voltage panels make in the cold.

How to use this calculator

  1. Enter the power station’s solar input limits from its manual.
  2. Enter one panel’s Voc, Isc, Vmp and Imp from its label or datasheet.
  3. Enter how many panels are in series and how many strings are in parallel.

How Solar Panel & MPPT Controller Compatibility Is Calculated

  • Cold open-circuit voltage = Voc × (1 + temperature coefficient × degrees below 25°C) × panels in series
  • Current = Isc (or Imp) × strings in parallel
  • Power = Vmp × Imp × panels in series × strings in parallel

Assumptions

  • Voltage coefficient is 0.30% per °C by default. Your datasheet lists the real value.
  • The coldest temperature is 0°C by default. Use the coldest morning where you will use the panels.
  • Series adds voltage and parallel adds current.

Solar Panel & MPPT Controller Compatibility Worked Example

  • Two 100 W panels in series (Voc 22.5 V, Isc 5.9 A, Vmp 18.5 V, Imp 5.4 A) into a station limited to 60 V, 15 A and 400 W.
  • Cold voltage is 22.5 × 1.075 × 2 = 48.4 V, current is 5.9 A and power is 200 W. All are within the limits.
  • Three of the same panels in series reach 72.6 V in the cold, above the 60 V limit. That can damage the station.

Common Solar Panel & MPPT Controller Compatibility Mistakes to Avoid

  • Checking voltage at 25°C only. Panels make more voltage when cold.
  • Adding panels in series without adding up their voltages.
  • Ignoring the connector type and polarity.

Solar Panel & MPPT Controller Compatibility Frequently Asked Questions

What are Voc and Isc?

Voc is the open-circuit voltage, the highest voltage a panel makes with nothing connected. Isc is the short-circuit current. Both are on the panel label.

Series or parallel?

Series adds voltage and keeps the current. Parallel adds current and keeps the voltage. Choose the layout that keeps both inside the station’s limits.

What if my panels make more power than the station accepts?

The station usually limits the input, so the extra is wasted. That is usually harmless if the voltage and current limits are met, but check your manual.